首页 > 国外线缆

[问题求助] 求助,UL 1581 导体 ASTM B、C、D类有什么区别?

P:2011-10-27 10:28:20

1

如题,请教高手指点一下。

GM - global module全局模块 (1) 投诉

P:2011-10-27 11:38:17

2

我也正想知道,搞不清楚,懂的解答一下

MEPR - medium ethylene propylene rubber中级乙丙橡胶 (0) 投诉

P:2011-10-27 17:16:18

3

Class AA—For bare conductors usually used in overhead lines.

Class A—For conductors to be covered with weatherresistant (weather-proof), slow-burning materials, and for bare conductors where greater flexibility than is afforded by Class AA is required.

Class B—For conductors to be insulated with various materials such as rubber, paper, varnished cloth, and so forth, and for the conductors indicated under Class A where greater flexibility is required.

Class C and Class D—For conductors where greater flexibility is required than is provided by Class B conductors.

concentric lapping machine - 同心式绕包机 (1) 投诉

P:2011-10-28 08:48:42

4

另外: Class G—Conductors consisting of 7 to 61 rope-laystranded
members, each of which consists of 7 to 19
concentric-stranded wires, with total conductor sizes ranging
from No. 14 AWG (2.08 mm2) to 5 000 000 cmil (2534 mm 2).
(Typical use is for rubber-sheathed conductor, apparatus conductor,
portable conductor, and similar applications.)

Class H—Conductors consisting of 19 to 91 rope-laystranded
members, each of which consists of 7 to 19
concentric-stranded wires, with total conductor sizes ranging
from No. 9 AWG (6.63 mm2) to 5 000 000 cmil (2534 mm 2).
Class K construction produces a conductor with greater flexibility
than class G. (Typical use is for rubber-sheathed cord
and applications where flexibility is required such as on
take-up reels over sheaves and extra-flexible apparatus conductor.)

Class I—Conductors consisting of wires 0.0201 in.
(0.511 mm) diameter (No. 24 AWG) to produce rope-laystranded
conductors up to 2 000 000 cmil (1013 mm2) in total
cross-sectional area. (Typical use is for special apparatus
conductor.)

Class K—Conductors consisting of wires 0.0100 in.
(0.254 mm) diameter (No. 30 AWG) to produce rope-laystranded
conductors up to 1 000 000 cmil (507 mm2) in total
cross-sectional area. (Typical use is for special portable cord
and conductors.)

Class M—Conductors consisting of wires 0.0063 in.
(0.160 mm) diameter (No. 34 AWG) to produce rope-laystranded
conductors up to 1 000 000 cmil (507 mm2) in total
cross-sectional area. (Typical use is for welding conductors.)

premise distribution system - 室内配线系统 (0) 投诉

P:2011-10-28 08:51:06

5

Class A, B, C, D的要求在ASTM B8里面;
Class G, H的要求在ASTM B173里面;
Class I, K, M的要求在ASTM B 172里面.

欢迎大家学习和交流.

SEACOM - South-East Asia Commonwealth Cable东南亚国家海底电缆 (1) 投诉

P:2011-10-28 14:51:07

6

Detailed explain. Thanks a lot!

dual take-up reel - 双式收线盘 (0) 投诉

P:2011-10-28 15:04:40

7

gas-impregnated cable - 气浸渍电缆,充气电缆 (0) 投诉

P:2011-10-28 17:09:03

8

谢谢,学习了

high performance drawing line - 高性能拉线生产线 (0) 投诉

P:2011-11-21 16:47:52

9

很好的资料,多谢了。

high pot test - 耐压试验,耐电压试验 (0) 投诉

P:2012-10-15 11:35:17

10

good job!

low frequency - 低频 (0) 投诉

P:2012-10-26 08:02:05

11

不错

snake closer - 蛇形绞合机 (0) 投诉

P:2012-11-05 08:58:56

12

学习了!

enamel applicator - 涂漆装置 (0) 投诉

P:2012-11-14 14:48:06

13

感谢啊,好贴啊

double shield - 双屏蔽 (0) 投诉

P:2014-10-23 14:23:20

14

感谢啊,好贴啊

Oval - 椭圆形 (0) 投诉

P:2014-11-03 20:01:21

15

刚好用到,非常好的资料~

AU access point - 管理单元跨接点 (1) 投诉

18


你需要登录才能发表,点击登录