首页 > 电气装备用线缆
[布电线缆] 求助227IEC53电缆规格知识
P:2008-03-11 11:58:25
4
敬请参阅:
| CCC RVV300/300V,RVV300/500V | |||||||
| 国标软线 | |||||||
| 类型Type | 导体Conductor | 绝缘Insulation | 护套Jacket | Min.resistance of Insulation at 70℃ | |||
| Cross area | No. | No./mm | Nom.Thickness | Nom.Thickness | Diameter(mm) (Approx.) | ||
| 227 IEC 52(RVV) | 0.5(Flat) | 2 | 16/0.2 | 0.5 | 0.6 | 3.0×4.8-3.6×6.0 | 0.012 |
| 0.5 | 2 | 16/0.2 | 0.5 | 0.6 | 4.8-6.0 | 0.012 | |
| 3 | 16/0.2 | 0.5 | 0.6 | 5.0-6.2 | 0.012 | ||
| 0.75(Flat) | 2 | 24/0.2 | 0.5 | 0.6 | 3.2×5.2-3.9×6.4 | 0.010 | |
| 0.75 | 2 | 24/0.2 | 0.5 | 0.6 | 5.2-6.4 | 0.010 | |
| 3 | 24/0.2 | 0.5 | 0.6 | 5.4-6.8 | 0.010 | ||
| 227 IEC 53(RVV) | 0.75(Flat) | 2 | 24/0.2 | 0.6 | 0.8 | 3.8×6.0-5.2×7.6 | 0.011 |
| 0.75 | 2 | 24/0.2 | 0.6 | 0.8 | 6.0-7.6 | 0.011 | |
| 3 | 24/0.2 | 0.6 | 0.8 | 6.4-8.0 | 0.011 | ||
| 4 | 24/0.2 | 0.6 | 0.8 | 6.8-8.6 | 0.011 | ||
| 5 | 24/0.2 | 0.6 | 0.9 | 7.4-9.6 | 0.011 | ||
| 1.0 | 2 | 32/0.2 | 0.6 | 0.8 | 6.4-8.0 | 0.010 | |
| 3 | 32/0.2 | 0.6 | 0.8 | 6.8-8.4 | 0.010 | ||
| 4 | 32/0.2 | 0.6 | 0.9 | 7.6-9.4 | 0.010 | ||
| 5 | 32/0.2 | 0.6 | 0.9 | 8.3-10.0 | 0.010 | ||
| 1.5 | 2 | 30/0.254 | 0.7 | 0.8 | 7.4-9.0 | 0.010 | |
| 3 | 30/0.254 | 0.7 | 0.9 | 8.0-9.8 | 0.010 | ||
| 4 | 30/0.254 | 0.7 | 1.0 | 9.0-11.0 | 0.010 | ||
| 5 | 30/0.254 | 0.7 | 1.1 | 10.0-12.0 | 0.010 | ||
| 2.5 | 2 | 50/0.254 | 0.8 | 1.0 | 8.9-11.0 | 0.009 | |
| 3 | 50/0.254 | 0.8 | 1.1 | 9.6-12.0 | 0.009 | ||
| 4 | 50/0.254 | 0.8 | 1.1 | 10.5-13.0 | 0.009 | ||
| 5 | 50/0.254 | 0.8 | 1.2 | 11.5-14.0 | 0.009 | ||
| 说明: | |||||||
| 1.额定温度:70℃ | |||||||
| 2.额定电压:300/300V,300/500V | |||||||
| 3.导体使用裸铜绞合线 | |||||||
| 4.标准:GB5023,IEC 60227-3 | |||||||
| 5.PVC绝缘 | |||||||
| 6.PVC护套 | |||||||
OF - optical fiber光纤 (0) 投诉