首页 > 国外线缆

[问题求助] UL2464是屏蔽线材吧

P:2008-03-21 11:32:26

1

UL2464 是屏蔽线材吧

 

plastic extrusion section - 挤塑工段 (0) 投诉

P:2008-03-21 12:00:44

2

看你要做哪一类的拉,也有非屏蔽的

cumm - cubic millimeter立方毫米 (0) 投诉

P:2008-03-21 12:01:18

3

可以是也可以不是,UL2464可以设计成好多种规格

water application guide - (浇铸机的)导水槽 (0) 投诉

P:2008-03-21 14:34:17

4

不一定是屏蔽呀,但一定是兩芯以上的線材!!!

small-seetion rolling mill - 小截面型线轧机 (0) 投诉

P:2008-03-25 08:33:52

5

 

UL1571 30V 80C,16-30AWG 电子电器内部连接,笔记本变压器线

UL1185,300V 80 C单芯屏蔽线,30-4AWG 单根或者裸铜,镀锡铜丝,用于录放音系统,电子电路等

UL1095 300V 80C 30AWG-16AWG 电子电器内部连接

  UL2464,300V 80 C电脑线,无屏蔽,单屏蔽,双屏蔽,30AWG-18AWG 绞合裸铜,镀锡铜丝,电子电器内外部连接线

UL2468,300V 80 C排线,30WAG-16AWG 单根,绞合铜丝,电器电脑内部连接线

UL2517 /2464/20276-SSS ,300V 105° 28-16AWG 移动线缆,电子电器,通用线缆,机器人用线缆

UL2547,80° 多芯屏蔽线缆80C,30-16AWG 2-3芯,录放音响电子系统

UL2651 排线300V 105C灰排彩排线,用于IDC 连接器配合PICH 2.54/2.0/1.27/1.0MM

  UL2725,30V 80 C 30-28AWG 2-13芯,用于2类系统视听电子设备内外部连接线

UL2835 30V 60C,屏蔽,无屏蔽,32-22AWG 用于2级电路电子设备内部连接线,游戏机线

draw-pak - 筒式拉线机,拉线筒 (1) 投诉

P:2008-04-17 19:36:03

6

2楼说的不错  很专业

bisector - (数学) 二等分线, 平分线 (0) 投诉

P:2008-04-24 17:14:05

7

哪位大侠有UL2464对绞线与总绞线的测试报告

automatic fixing of wire end - 线头的自动固定(线盘表面上的) (0) 投诉

P:2008-05-14 19:11:04

8

UL2464线的标准有吗?

bevel roll - 斜辊,锥形轧辊 (0) 投诉

P:2010-05-05 19:30:22

9

UNDERWRITERS LABORATORIESAPPLIANCE WIRING MATERIAL
Subj.758Section 2Page 2464Issued:1968-05-02
Revised:2009-05-26
Style 2464Jacketed Cable.

Rating80 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional.
BraidOptional, provided over Jacket.
JacketPVC
Dia of Cable under jacketMin averageMinimum at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
2.501-4.000 inch110 mils88 mils
4.001 inch and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment (such as desk-type calculators, dictating machines, or x-ray equipment).

帖 子 奖 罚
zhengliang 奖励 10 金币,.05 声望,于 2010-10-30 20:08:06 原因:應助

threading - 穿线,穿模 (0) 投诉

P:2010-05-28 11:07:02

10

UL2464是可做屏蔽线也可做非屏蔽线的.SHIELD OPTIONAL是屏蔽可选的意思,也意味着没有屏蔽也可以的.

TAA - 表示线包铜导体 PTFE 包带,毡状石棉绝缘花线,外以石棉编织,使用温度200℃。 (0) 投诉

P:2010-06-01 21:38:20

11

屏蔽是可选择的 shield  optional

motoreducer - 马达减速器 (0) 投诉

P:2010-06-02 14:04:58

12

UL 2464可以做屏蔽或非屏蔽

SCTE - Society for Cable Television Engineering电缆电视工程协会 (0) 投诉

P:2010-06-02 20:13:14

13

按客户要求做么 客户要求屏蔽就可以做

paste - 膏,胶,浆糊 (0) 投诉

P:2010-07-29 16:05:59

14

 不一定,有屏蔽和非屏蔽的

protective casing - 防护罩 (0) 投诉

P:2010-08-09 14:05:23

15

continuous casting - 连续浇铸,连铸 (0) 投诉

27