首页 > 国外线缆

[问题求助 ] UL 2733电线最大直径可以做多大?

P:2021-11-23 08:36:40

1

请教大家UL 2733电线最大直径可以做多大?有相关标准吗?谢谢!

XOH - cross-office highway局间信息高速公路 点赞(0) 投诉

P:2021-11-23 13:49:10

2

APPLIANCE WIRING MATERIAL

Subj.758
Section 2
Page 2733
Issued: 1975-06-23
Revised: 2012-07-10
Style 2733
 
Multiple Conductor Cable using Non-Integral Extruded Jacket
RATING
105 deg C, 600 Vac, Horizontal Flame.
INSULATION
Labeled Style 1015
ASSEMBLY
Two to seven conductors cabled together. Length of lay not specified. Fillers optional. Maximum diameter of cable assembly under jacket is 0.350 inches.
JACKET
Extruded PVC, 15 mils minimum average, 12 mils minimum at any point.
STANDARD
Appliance Wiring Material UL 758.
MARKING
General.
USE
Internal Wiring.                                                                                    这是UL对UL2733的要求,另外还要看你们自己的活页。

rubber-endplate - 橡皮端板(光纤连接盒的) 点赞(1) 投诉

P:2021-11-26 11:09:35

3

WHP2016:

APPLIANCE WIRING MATERIAL

Subj.758

Section 2

Page 2733

Issued: 1975-06-23

Revised: 2012-07-10

Style 2733

 

Multiple Conductor Cable using Non-Integral Extruded Jacket

RATING

105 deg C, 600 Vac, Horizontal Flame.

INSULATION

Labeled Style 1015

ASSEMBLY

Two to seven conductors cabled together. Length of lay not specified. Fillers optional. Maximum diameter of cable assembly under jacket is 0.350 inches.

JACKET

Extruded PVC, 15 mils minimum average, 12 mils minimum at any point.

STANDARD

Appliance Wiring Material UL 758.

MARKING

General.

USE

Internal Wiring.                                                                                    这是UL对UL2733的要求,另外还要看你们自己的活页。


peiletizer - 切粒机,制粒机,切片机 点赞(0) 投诉

P:2021-11-26 11:10:25

4

WHP2016:

APPLIANCE WIRING MATERIAL

Subj.758

Section 2

Page 2733

Issued: 1975-06-23

Revised: 2012-07-10

Style 2733

 

Multiple Conductor Cable using Non-Integral Extruded Jacket

RATING

105 deg C, 600 Vac, Horizontal Flame.

INSULATION

Labeled Style 1015

ASSEMBLY

Two to seven conductors cabled together. Length of lay not specified. Fillers optional. Maximum diameter of cable assembly under jacket is 0.350 inches.

JACKET

Extruded PVC, 15 mils minimum average, 12 mils minimum at any point.

STANDARD

Appliance Wiring Material UL 758.

MARKING

General.

USE

Internal Wiring.                                                                                    这是UL对UL2733的要求,另外还要看你们自己的活页。



谢谢!请问活页在哪里找,怎样才可以看见?


spray jet - 喷嘴 点赞(0) 投诉

4


你需要登录才能发表,点击登录