首页 > 国外线缆
[问题求助] ul 20895 材料
P:2008-12-12 21:53:19
2
UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL |
Subj.758 | Section 2 | Page 20895 | Issued:1995-08-11 |
Revised:2008-05-27 |
Style 20895 | Jacketed Cable. |
Rating | 90 deg C, 1000 Vac, Cable flame. |
Conductor | 40 AWG min - Material not specified. |
Insulation | Labeled or complies with manufacturer's AWM Procedure. |
Assembly | Two or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer over cable core or individual singles and/or fillers optional, manufacturer shall maintain a complete description of each assembly. |
Shield | Optional. May be over one or more of the insulated conductors or applied over the assembly. |
Jacket | PUR - See Facing Page for Compound |
dia in inches of 0.425 or less | 50 mils min average | 40 mils minimum at any point |
0.426-0.700 dia | 66 avg | 52 min |
0.701-1.500 dia | 88 avg | 70 min |
1.501-2.500 dia | 120 avg | 96 min |
2.501 dia and larger | 154 avg | 124 min |
Standard | Appliance Wiring Material UL 758. |
Marking | General. |
Use | As internal wiring or external interconnection of electronic equipment (such as computers and business machines). |
EDM - electro-discharge machining电火花加工(拉线模) (0) 投诉
4