首页 > 新手区
[问题求助] XLPE
P:2010-12-17 15:27:16
4
| UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL | ||||
| Subj.758 | Section 3 | Page 3302 | Issued:1975-11-13 |
| Revised:2010-04-23 | |||
| Style 3302 | Insulated Wire | |
| Rating | 105 deg C, 30 Vac, Horizontal flame. |
| Conductor | 40 AWG minimum, material not specified. |
| Insulation | Solid or cellular XLPE, 4 mils min at any point, 100 mils maximum. |
| Shield | Optional |
| Jacket | (Optional) PVC: 5 mils min at any point, 100 mils maximum. May be irradiated. |
| Standard | Appliance Wiring Material UL 758. |
| Marking | General. |
| Use | Internal Wiring of Class 2 Circuits in Electronic Equipment. |
更具体的标准在UL758和UL1581中查询
FTTD - fiber-to-the-desk光纤到桌面 (0) 投诉
6