首页 > 国外线缆
[问题求助] 那位知道UL1435的结构
P:2011-11-28 17:16:35
3
UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL |
Subj.758 | Section 1 | Page 1435 | Issued:1967-07-14 |
Revised:2008-05-27 |
Style 1435 | Jacketed wire. |
Rating | 80 deg C, 300 Vac, Horizontal flame. |
Conductor | 30 AWG - 10 AWG solid or stranded round, tinned or bare copper. |
Insulation | Solid or cellular FRPE or PE, for 30-16 AWG, 15 mils min. average, 13 mils minimum at any point. For 15-20 AWG, 20 mils min. avg, 18 mils min. at any point. |
Assembly | Insulated conductor built with optional barrier tape, optional shield, optional covering, optional shield and required jacket. |
Shield | Optional. |
Covering | Optional. A textile braid, nylon jacket (2 mil min thickness), or min 8 mils of semi-rigid or regular PVC may be applied between the insulation and shield |
Jacket | PVC, 15 mils min average, 12 mils minimum at any point. |
Misc. | Optional Barrier Tape - Polyester tape. |
Standard | Appliance Wiring Material UL 758. |
Marking | General. |
Use | Internal wiring of electronic equipment. |