电线电缆网 > 国外线缆 > UL 2464标准(完整版)
UL 2464标准 - 无图版
zhuguan --- 2007-11-19 08:53:01
1
求助
2464标准
goldentang --- 2007-11-19 10:01:40
2
额度温度:80℃
额度电压:300V
标准:UL758,UL1581,及CSA C22.2NO.210.2
导体使用镀锡铜线或绞合裸铜。
半硬质聚氯乙烯绝缘
芯线绞合后拖包铝箔夹拉带屏蔽
镀锡或裸铜绞合地线
裸铜或镀锡铜线编织至95%遮蔽率
聚氯乙烯护套
通过UL VW-1SC及CSA FT1垂直耐燃测试
应用于电子设备内部及外部连线
810707 --- 2007-11-19 10:36:27
3
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 2 Page 2464 Issued: May 2, 1968
Revised: Dec. 22, 1986
Style 2464 PVC Jacketed Cable.
______________________________________________________________________________
Rating
______________________________________________________________________________
Insulated Labeled or complying with manufacturer's AWM Procedure
Conductors having a minimum rating of
______________________________________________________________________________
Assembly Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles
may be laid parallel to form flat, oval or round cable.
Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
______________________________________________________________________________
Covering (Optional) A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
______________________________________________________________________________
Shield (Optional) Page 24.
______________________________________________________________________________
Jacket PVC - Class 43
THICKNESS OF PVC JACKET (mils)
#Dia. of Cable Minimum
Under Jacket Minimum at any
in Inches. Average point
0.700 or less 30 24
0.701 - 1.000 45 36
1.001 - 1.500 60 48
1.501 - 2.500 80 64
2.501 - 4.000 110 88
4.001 or larger 140 112
# Major dia if cable is flat or oval.
______________________________________________________________________________
*Standard Test Reference Standard - UL 1581.
______________________________________________________________________________
(Continued on Page
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 2 Page
Revised: Dec. 22, 1986
Instructions Detailed examination of the cable assembly and jacket.
to UL Physical Properties of Jacket, Page 32.
Representative Dielectric Strength Test, 1500 Volts, (Shielded cable only), Page 96.
The designation of all Styles of the individual conductors used making up the cable assembly shall be available, and the UL Representative’s tag shall indicate if the Style is
labeled or not. If they are not labeled, the appropriate
Follow-Up Tests shall be conducted.
______________________________________________________________________________
UL (4) Detailed Examination.
Counter-Check (4) Physical Properties of Jacket, Page 33.
Program (2) Heat Shock on jacket, Page 57.
(2) Deformation on Jacket, Class 43.
(4) Cold Bend on completed cable, Page 58.
(2) Flame Test on completed cable, Page 95.
If the insulated styles are not labeled, the appropriate Follow-Up Tests shall be conducted.
______________________________________________________________________________
Marking General, Page 13.
______________________________________________________________________________
*Use Internal wiring or external interconnection of electronic equipment (such as desk-type calculators, dictating machines, or x-ray equipment).
BAIDMQ --- 2007-11-19 11:47:16
4
对了,UL2464中没有规定导体的范围,但UL1061的范围是30-16AWG,那UL2464的导体范围是多少呢?请哪位告知。
goldentang --- 2007-11-19 12:03:24
5
jackeyli --- 2007-11-19 13:57:43
6
孙汉明 --- 2007-11-19 18:26:58
7
楼上的别误导别人啊,2464的额定温度为80,额定电压为300V,2464内部的电子线的额定温度及额定电压就应该大于或等于2464的额定温度及额定电压,也就是说导体的范围跟着内部电子线走啊!1061能做30-16AWG,那2464也能做30-16AWG
是这样的,只要符合要求的都是可以的
ok509 --- 2007-11-19 19:26:14
8
weajee --- 2008-09-27 19:26:47
9
CHUNLI --- 2008-09-29 16:37:05
10
李小龍 --- 2008-09-30 11:43:17
11
生活 --- 2008-10-14 15:50:05
12
军军 --- 2008-10-15 11:21:45
13
AbelGuo --- 2008-10-15 11:39:55
14
6L说的对 。。
Style Page论坛有吧
军军 --- 2008-10-17 15:41:52
15
Style Page论坛?网址是哪个啦?麻烦楼上大哥告诉我一下啦
RENBOBAFO --- 2008-11-12 09:07:48
16