电线电缆网 > 国外线缆 > UL线材资料标准在哪里找得到?(完整版)

UL线材资料标准在哪里找得到? - 无图版

youyucs63 --- 2008-07-14 08:30:31

1

想请教一下,UL线材的标准在哪里可以找到,如UL1061/UL1007电子线,<线材结构,导体结构,绝缘材质,印字的内容,印字的颜色,字高等>,这些相关的资料在哪一个标准里找得到?
qinys --- 2008-07-14 09:31:35

2

UL 758   UL1581 还有UL STAL PAGE 1061 1007,有你需要的标准内容

小草的世界 --- 2008-07-15 17:43:06

3

在这里搜下不就得了~~~~~~~

 

 

youyucs63 --- 2008-07-17 09:10:16

4

伤脑筋,我就是没有找到才会问的,UL758里面什么都没有
yuxuang --- 2008-07-17 21:35:00

5

UL1581里有規定啊

 

youyucs63 --- 2008-07-18 20:11:28

6

怎么我找不到相关的资料,UL1581有206页,请问在哪几页
SHIZI28 --- 2008-07-24 20:44:55

7

看看這個,是否對你有幫助.UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 1 *Page 1061 Issued: May 1, 1959
Revised: June 20, 2001
Style 1061 Special PVC - Insulated Wire.
Rating 80°C, 300 Volts.
Conductor No. 30-16 AWG, solid or stranded, tinned or bare copper.
*
Insulation Extruded Semi-Rigid PVC: 9 mil average, 7 mil minimum at any
point.
Standard Appliance Wiring Material UL 758.
Instructions
to UL
Representative
Detailed Examination.
Physical Properties, unaged.
Flexing.
Spark Test.
UL
Counter-Check
Program
(4) Detailed Examination.
(4) Physical Properties, unaged.
(4) Heat Shock.
(4) Deformation.
(4) Cold Bend.
(4) Horizontal Flame Test.
Marking General.
Use Internal Wiring in Electric Bookkeeping, Accounting,
Time-Recording Machines, or Electronic Equipment if
within a chassis or protected from mechanical injury.

 

 

UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 1 *Page 1007 Issued: May 1, 1959
Revised: June 20, 2001
Style 1007 Polyvinyl Chloride Insulated Wire.
____________________________________________________________________________
Rating 80°C, 300 V.
____________________________________________________________________________
Conductor 32-16 AWG, solid or stranded.
____________________________________________________________________________
Insulation Polyvinyl Chloride, 15-Mils minimum average,
13 mils minimum at any point, 60 or 80°C in oil,
if applicable.
_____________________________________________________________________________
Standard Appliance Wiring Material UL 758.
_____________________________________________________________________________
Instructions Detailed Examination.
to UL Physical Properties, unaged.
Representative Spark Test.
_____________________________________________________________________________
UL (4) Detailed Examination.
Counter-Check (4) Physical Properties.
Program (4) Heat Shock.
(4) Cold Bend
(4) Horizontal Flame Test.
(4) Deformation.
_____________________________________________________________________________
Marking General.
_____________________________________________________________________________
Use Internal wiring of Appliances; or where exposed to oil at
a temperature not exceeding 60°C or 80°C, whichever is
applicable. Tags may indicate the following: 600 V Peak -
For Electronic Use Only.

albertsun --- 2009-03-24 12:37:33

8

樓上之真是好人一個

-- 结束 --