电线电缆网 > 国外线缆 > 【已经解决】UL 2464 电线一般多是两芯 和两芯以上的 是否可生产 一芯的?(完整版)
【已经解决】UL 2464 电线一般多是两芯 和两芯以上的 是否可生产 一芯的? - 无图版
SHYQPHY --- 2010-03-09 19:16:23
1
[xie 在 2010-11-10 11:14:54 编辑过]
lyp8866 --- 2010-03-09 20:00:15
2
fourwo --- 2010-03-09 21:29:00
3
怎么肯能……
一芯的都是1或3打头的……
看来你只是随便问问……
想到什么随便说说吧……
maxxiao --- 2010-03-10 09:48:01
4
ms02043109 --- 2010-03-10 11:28:42
5
可以做1C 印UL 2464 ,但线记得自己珍藏就好了。。。
wzhtdxdl --- 2010-03-10 12:42:47
6
zeng147147 --- 2010-03-12 15:46:03
7
fourwo:怎么肯能……
一芯的都是1或3打头的……
看来你只是随便问问……
想到什么随便说说吧……
jxhuaqing --- 2010-03-16 15:13:59
8
xue --- 2010-03-21 19:53:58
9
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 2464 Issued: 1968-05-02
Revised: 2003-05-02
Style 2464 PVC Jacketed Cable.
______________________________________________________________________________
Rating 80°C, 300 V.
______________________________________________________________________________
Insulated Labeled or complying with manufacturer's AWM Procedure
Conductors having a minimum rating of 80°C and 300 V.
______________________________________________________________________________
Assembly Two or more singles, twisted pairs of groups of twisted
singles twisted together or singles or groups of singles
may be laid parallel to form flat, oval or round cable.
Lay not specified. Barrier layer and/or fillers optional.
Manufacturer shall maintain a complete description of each
assembly. May use same or mixed AWG size.
______________________________________________________________________________
*Covering (Optional).
______________________________________________________________________________
Shield Optional.
______________________________________________________________________________
Jacket PVC - Class 43
THICKNESS OF PVC JACKET (mils)
#Dia. of Cable Minimum
Under Jacket Minimum at any
in Inches. Average point
0.700 or less 30 24
0.701 - 1.000 45 36
1.001 - 1.500 60 48
1.501 - 2.500 80 64
2.501 - 4.000 110 88
4.001 or larger 140 112
# Major dia if cable is flat or oval.
______________________________________________________________________________
Braid Optional.
______________________________________________________________________________
Standard Appliance Wiring Material UL 758.
______________________________________________________________________________
(Continued on Page 2464A)
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 2464A Issued: 1968-05-02
Revised: 2003-05-02
Instructions Detailed Examination of the cable assembly and jacket.
to UL Physical Properties of Jacket.
Representative Dielectric Strength Test, 1500 Volts (shielded cable only).
The designation of all Styles of the individual conductors used making up the cable assembly shall be available, and the UL Representative’s tag shall indicate if the Style is labeled or not. If they are not labeled, the appropriate Follow-Up Tests shall be conducted.
______________________________________________________________________________
UL (4) Detailed Examination.
Counter-Check (4) Physical Properties of Jacket.
Program (4) Heat Shock on Jacket.
(4) Deformation on Jacket, Class 43.
(4) Cold Bend on Completed Cable.
(12) Cable Flame Test on Completed Cable.
If the insulated styles are not labeled, the appropriate Follow-Up Tests shall be conducted.
______________________________________________________________________________
Marking General.
______________________________________________________________________________
Use Internal wiring or external interconnection of electronic
equipment (such as desk-type calculators, dictating
machines, or x-ray equipment).
hrbdgxy --- 2010-03-24 12:49:01
10
sweeting --- 2010-06-11 15:29:52
11
李小龍 --- 2010-06-11 17:31:54
12
IJXXIADX --- 2010-06-12 08:57:09
13
lsdb2008 --- 2010-06-25 14:35:04
14
不可以生产成一芯的,
UL电线命名的时候对电线的结构都有规定的。
HYQ0512 --- 2010-06-28 15:13:39
15
至于UL2464能不能做单芯的,取决于自己的胆量……
dingsl201 --- 2010-07-07 09:01:15
16
UL2464中的2告诉你:no
相信刘翔 --- 2010-07-07 21:12:28
17
koulf --- 2010-11-02 15:49:22
18