电线电缆网 > 国外线缆 > UL2464地线问题???(完整版)

UL2464地线问题??? - 无图版

APENG88 --- 2010-07-10 16:05:26

1

请问一下,有没有人在抽UL2464等线材时,地线用单芯线来放的?UL标准可不可以用单芯线来放?
moveitgogo --- 2010-07-10 19:29:15

2

你的单芯线是什么意思?单根导体?如果是,当然可以了!没有要求的。
zhongming --- 2010-07-11 14:38:18

3

没有听明白意思

晨曦1394 --- 2010-07-11 19:53:12

4

没有要求的
long9590 --- 2010-07-16 14:10:04

5

Style 2464Jacketed Cable.

Rating80 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional.
BraidOptional, provided over Jacket.
JacketPVC
Dia of Cable under jacketMin averageMinimum at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
2.501-4.000 inch110 mils88 mils
4.001 inch and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
long9590 --- 2010-07-16 14:12:25

6

上面是UL2464的标准,你谈的问题是没有规定的,只要护套最小厚度和绝缘等级符合,结构你自己发挥.
-- 结束 --