电线电缆网 > 国外线缆 > UL STYLE PAGE 2060求助资料(完整版)

UL STYLE PAGE 2060求助资料 - 无图版

nancy9718 --- 2010-10-19 14:22:21

1

各位好!

煩請幫忙提供一下UL STYLE PAGE 2060資料;

急需!

謝謝!

heshuxin --- 2010-10-19 14:34:29

2

UL 758 中的 2060

60, 80, 90, 105 额定温度

22-16AWG  镀锡或裸铜线导体结构

PVC聚氯乙烯    绝缘    类似SPT-2结构

1.14 /1.02mm 绝缘厚度(平均/最小)

撕开后最小绝缘厚度为:0.69mm

导体间距为:2.03mm

用于控制线的吹风机或暖气片或电热毯;或电风扇的内部布线

若有疑问:QQ:282751448

 

 

nancy9718 --- 2010-10-19 14:37:19

3

謝謝!

有標準的UL資料嗎?

 

Ares --- 2010-10-19 14:53:01

4

UNDERWRITERS LABORATORIESAPPLIANCE WIRING MATERIAL
Subj.758Section 2Page 2060Issued:1959-05-01
Revised:2008-05-27
Style 2060Integral Parallel Cable

Rating60, 80, 90 or 105 deg C, 300 Vac, Horizontal flame.
Conductor22 AWG - 16 AWG, tinned or bare copper.
InsulationIntegral with Jacket. PVC, 45 mils minimum average before separation, 40 mils minimum at any point before separation, 27 mils minimum at any point after separation, 80 mils minimum thickness of web between conductors.
AssemblyTwo, three or four conductors, same as for Type SPT-2.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseControl wire on hair dryers or heating pads or on electric blankets; or Internal wiring of electric fans.


 

 

nancy9718 --- 2010-10-26 11:31:19

5

謝謝啦!!!

Danielle --- 2019-05-06 18:31:15

6

这款线材关于ROLL FLEXIBILITY测试方法是怎么样的呢?