电线电缆网 > 国外线缆 > 问1016 在UL STYLE PAGE 规定导体做28-9AWG,但我们客户要求做30AWG(完整版)
问1016 在UL STYLE PAGE 规定导体做28-9AWG,但我们客户要求做30AWG - 无图版
awzh5184 --- 2011-08-18 23:36:19
1
请问1016 在UL STYLE PAGE 规定导体做28-9AWG,但我们客户要求做30AWG,请问可以做不?
bsdtdw --- 2011-08-19 08:45:47
2
当然不可以
Killer009 --- 2011-08-19 09:26:39
3
不印字就可以
晨曦1394 --- 2011-08-19 12:05:09
4
做非標嘛,不要印1061就OK了。
pwenhuan --- 2011-08-19 14:33:14
5
Style 1061 | SRPVC Insulated Wire. |
Rating | 80 deg C, 300 Vac, Horizontal flame. |
Conductor | 30 AWG - 10 AWG solid or stranded. |
Insulation | SRPVC, 9 mils minimum average, 7 mils minimum at any point. |
Standard | Appliance Wiring Material UL 758. |
Marking | General. |
Use | Internal Wiring in Electric Bookkeeping, Accounting, Time-Recording Machines, or Electronic Equipment if within a chassis or protected from mechanical injury. |
pwenhuan --- 2011-08-19 14:37:50
6
可以做到30#啊
286052293 --- 2011-08-19 14:44:40
7
麻烦楼上的大哥看清楚好不好,人家说的是1016,你发个1061干什么??
不符合标准的线肯定不行的
但非标的什么线做不出来??
albert0829 --- 2011-08-20 12:59:38
8
可以推荐客人使用UL1015,UL1015可以做30AWG,电压和温度与UL1016一样,厚度也相差无几。
lsdb2008 --- 2011-08-24 13:19:02
9
不可以,
很显然,不符合标准要求。
7334laomai --- 2011-08-24 19:53:25
10
wzhtdxdl --- 2011-08-26 08:53:31
11
你们公司没达到30#不代表别人不行。。。
Phanllina --- 2011-08-29 09:38:30
12
以下红色字体意思是不是说要加押一层尼龙?如果是,怎么可以UL1015这些线代? Style 1016 Polyvinyl Chloride Insulated Wire.______________________________________________________________________________ Rating 105°C, 600 Volts.______________________________________________________________________________ Conductor 28-9 AWG, Solid or Stranded, tinned or bare copper.______________________________________________________________________________ Insulation Polyvinyl Chloride, 31 mils minimum average, 28 mils minimum at any point, compounds suitable for use at 105°C in air and 60°C or 80°C in oil.______________________________________________________________________________ *Covering Extruded nylon in 2-mil minimum thickness or lacquered braid._______________________________________
sophere --- 2011-09-07 19:59:07
13
看一下你们公司的facing page有没有说要做Covering 的,如果有限制不做Covering的,那就可以用UL1015来代了。
jolinchen --- 2011-09-14 21:10:36
14
不符合UL標準肯定是不能做的?此點可以跟你客戶說明,可以建議用1015代替.
不符合都去做,那不是自己欺騙自己嘛,何況到時被UL查到還要被開VN.
IJXXIADX --- 2011-10-11 14:43:19
15
一張VN幾多錢?
yjmcl --- 2011-10-18 20:35:18
16
1015代替呗~ 跟客户说好,要么做个非标的也行哈
onewindy --- 2013-06-19 10:45:12
17
可以换个STYLE PAGE号就行了。