电线电缆网 > 国外线缆 > 1007线材是怎样的结构。怎样设计(完整版)
1007线材是怎样的结构。怎样设计 - 无图版
zkxx --- 2007-05-18 10:12:07
1
我是新的设计人员,求助???
周永初 --- 2007-05-19 11:41:23
2
很简单:
导体为镀锡软铜线,绝缘PVC,绝缘厚度0.38MM,
比如:
26AWG ID=1.3
28AWG ID=1.15
30AWG ID=1..0
24AWG ID=1.45
22AWG ID=1.6
AbelGuo --- 2007-05-22 09:06:56
3
电子线的设计导体:16-32AWG (Stranded And solid Tinned and bare)绝缘PVC 或SR-PVC 平均厚度:15Mils 最小为:13Mils
UL 758 AWM Style page 写的很清楚!!
luoxinqiao --- 2007-06-05 09:20:49
4
有要求一定要鍍錫嗎?好像沒有.
WONDERFUL --- 2007-06-14 09:32:45
5
看UL758吧!
2935316 --- 2007-06-25 14:05:09
6
去买一本标准,什么都清楚了!
youyucs63 --- 2007-07-20 16:03:12
7
由绞合好的镀锡铜和外被组合而成,导体型号由16AWG~28AWG,外被一般都用SR-PVC,还要油印字,
吕月白 --- 2007-07-20 20:30:18
8
知道标准的行家请把相关的条款告诉一下.
免得后辈花了大量的精力还是没有整明白.
还不如前辈们稍微指点一下就明白了~
是不是?
沙漠骆驼 --- 2009-01-19 11:06:41
9
平均厚度:15Mils 最小为:13Mils,这是标准厚度呀,跟我们所说的0.40mm有什么不同呀
wuxuner --- 2009-03-09 14:04:39
10
最小绝缘厚度达到0.33mm
szss73 --- 2009-04-27 15:25:56
11
还是不怎么明白
lluu --- 2009-04-27 18:27:16
12
不一定哦,要看你申请的时候授权给你做多厚才行哦!
jimwang --- 2009-05-05 22:38:09
13
1007是最简单的线,80度300V的,15MIL平均厚度,13MIL最小厚度,你没有通过认证是不能做的,只有通过认证才可以印UL标志的
jizhuan501 --- 2009-05-06 09:23:05
14
这属于电子线,相对比较简单点儿!
hushao --- 2009-05-06 11:28:50
15
UL style page
yy2008 --- 2009-05-06 11:41:39
16
对UL758活页里面对该款线材的结构、检验、检查要求写得很清楚的,
是设计、生产、检验、检查的依据。
LWGXINYA --- 2009-05-08 10:00:31
17
像这种简单的问题,看看别的公司或自己公司的产品目录,照个葫芦画个瓢就可以了
ceteight --- 2009-05-08 15:31:57
18
这个线是电线入门最基本的线材了,多看看别公司产品就会了。
做电线的 --- 2009-05-08 18:32:47
19
对头。。。看看别家公司的产品目录一下就知道了
推荐看看乐庭的。。。
做的挺全的
推荐看看乐庭的。。。
做的挺全的
芝麻开门了 --- 2009-05-11 17:21:05
20
到百度上搜一下,上面都有的。1007是最基础的线材,线径基本都已经在业内通用了。
Kining --- 2009-05-15 11:24:45
21
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 1 *Page 1007 Issued: May 1, 1959
Revised: June 20, 2001
Style 1007 Polyvinyl Chloride Insulated Wire.
____________________________________________________________________________
Rating 80°C, 300 V.
____________________________________________________________________________
Conductor 32-16 AWG, solid or stranded.
____________________________________________________________________________
Insulation Polyvinyl Chloride, 15-Mils minimum average,
13 mils minimum at any point, 60 or 80°C in oil,
if applicable.
_____________________________________________________________________________
Standard Appliance Wiring Material UL 758.
_____________________________________________________________________________
Instructions Detailed Examination.
to UL Physical Properties, unaged.
Representative Spark Test.
_____________________________________________________________________________
UL (4) Detailed Examination.
Counter-Check (4) Physical Properties.
Program (4) Heat Shock.
(4) Cold Bend
(4) Horizontal Flame Test.
(4) Deformation.
_____________________________________________________________________________
Marking General.
_____________________________________________________________________________
Use Internal wiring of Appliances; or where exposed to oil at
a temperature not exceeding 60°C or 80°C, whichever is
applicable. Tags may indicate the following: 600 V Peak -
For Electronic Use Only.
Subject 758 Section 1 *Page 1007 Issued: May 1, 1959
Revised: June 20, 2001
Style 1007 Polyvinyl Chloride Insulated Wire.
____________________________________________________________________________
Rating 80°C, 300 V.
____________________________________________________________________________
Conductor 32-16 AWG, solid or stranded.
____________________________________________________________________________
Insulation Polyvinyl Chloride, 15-Mils minimum average,
13 mils minimum at any point, 60 or 80°C in oil,
if applicable.
_____________________________________________________________________________
Standard Appliance Wiring Material UL 758.
_____________________________________________________________________________
Instructions Detailed Examination.
to UL Physical Properties, unaged.
Representative Spark Test.
_____________________________________________________________________________
UL (4) Detailed Examination.
Counter-Check (4) Physical Properties.
Program (4) Heat Shock.
(4) Cold Bend
(4) Horizontal Flame Test.
(4) Deformation.
_____________________________________________________________________________
Marking General.
_____________________________________________________________________________
Use Internal wiring of Appliances; or where exposed to oil at
a temperature not exceeding 60°C or 80°C, whichever is
applicable. Tags may indicate the following: 600 V Peak -
For Electronic Use Only.
Kining --- 2009-05-15 11:26:02
22
lwlmuzi520 --- 2009-05-15 15:23:48
23
UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL |
Subj.758 | Section 1 | Page 1007 | Issued:1959-05-01 |
Revised:2008-05-27 |
Style 1007 | Insulated Wire. |
Rating | 80 deg C, 300 Vac, Horizontal flame, Oil Resistant 60 deg C or 80 deg C (optional). |
Conductor | 32 AWG - 16 AWG Solid or Stranded. |
Insulation | PVC, 15 mils minimum average, 13 mils minimum at any point. |
Standard | Appliance Wiring Material UL 758. |
Marking | General. |
Use | Internal wiring of appliances; or where exposed to oil at a temperature not exceeding 60 deg C or 80 deg C, whichever is applicable. Tags may indicate the following: 600 V Peak - For Electronic Use Only. |
yy2008 --- 2009-05-15 16:40:01
24
赞成3楼意见,
AWM活页是ULAWM电线设计、生产、检验、检测、认证的依据.